| GensetModel | StandbyPower | PrimePower | PerkinsEngine | Specifications | ||||
| KW | KVA | KW | KVA | |||||
| XG-80GF | 80 | 100 | 75 | 93.75 | 1104C-44TAG1 | |||
| XG-100GF | 100 | 125 | 91 | 114 | 1104C-44TAG2 | |||
| XG-132GF | 132 | 165 | 120 | 150 | 1106A-70TAG2 | |||
| XG-200GF | 200 | 250 | 182 | 227 | 1306C-E87TAG4 | PDF | ||
| XG-220GF | 220 | 275 | 200 | 250 | 1306C-E87TAG6 | |||
| XG-300GF | 300 | 375 | 273 | 341 | 2206A-E13TAG2 | |||
| XG-330GF | 330 | 412.5 | 300 | 375 | 2206A-E13TAG3 | PDF | ||
| XG-360GF | 396 | 495 | 360 | 450 | 2506C-E15TAG1 | |||
| XG-380GF | 380 | 475 | 350 | 437.5 | 2506A-E15TAG1 | |||
| XG-440GF | 440 | 550 | 400 | 500 | 2506A-E15TAG2 | |||
| XG-550GF | 550 | 687.5 | 500 | 625 | 2806A-E18TAG2 | |||
| XG-640GF | 640 | 800 | 582 | 727 | 4006-23TAG2A | |||
| XG-700GF | 700 | 875 | 636 | 795 | 4006-23TAG3A | |||
| XG-770GF | 770 | 962.5 | 700 | 875 | 4008TAG1A | |||
| XG-850GF | 850 | 1062.5 | 780 | 975 | 4008TAG2A | |||
| XG-1000GF | 1000 | 1250 | 909 | 1136 | 4012-46TWG2A | |||
| XG-1200GF | 1200 | 1500 | 1091 | 1364 | 4012-46TAG2A | |||
| XG-1680GF | 1680 | 2100 | 1500 | 1875 | 4016TAG2A | |||
| XG-1800GF | 1800 | 2250 | 1636 | 2045 | 4016-61TRG3A | |||
| GensetModel | StandbyPower | PrimePower | Perkins Engine | Specifications | ||
| KVA | KW | KVA | KW | |||
| XG13S3-6 | 13 | 10 | 12 | 9 | 403D-11G | |
| XG20S3-6 | 20 | 16 | 18 | 14 | 403A-15G2 | |
| XG26S3-6 | 26 | 21 | 24 | 19 | 404D-22G | |
| XG35S3-6 | 35 | 28 | 32 | 26 | 404D-22TG | |
| XG40S3-6 | 40 | 31 | 35 | 28 | 1103A-33G | |
| XG59S3-6 | 59 | 47 | 53 | 42 | 1103A-33TG1 | |
| XG75S3-6 | 75 | 60 | 68 | 55 | 1103A-33TG2 | |
| XG85S3-6 | 85 | 68 | 78 | 62 | 1104A-44TG1 | |
| XG105S3-6 | 105 | 82 | 93 | 74 | 1104A-44TG2 | |
| XG125S3-6 | 125 | 100 | 112 | 90 | 1104C-44TAG2 | |
| XG190S3-6 | 190 | 150.4 | 169 | 135.2 | 1106A-70TAG2 | |
| XG220S3-6 | 220 | 176 | 200 | 160 | 1106A-70TAG3 | |
| XG250S3-6 | 250 | 200 | 225 | 180 | 1206A-E70TTAG1 | |
| XG395S3-6 | 395 | 300 | 357 | 270 | 1706A-E93TAG1 | |
| XG440S3-6 | 440 | 352 | 400 | 320 | 2206C-E13TAG2 | |
| XG500S3-6 | 500 | 400 | 438 | 350.4 | 2206A-E13TAG6 | |
| XG565S3-6 | 565 | 452 | 513 | 410 | 2506C-E15TAG1 | |
| XG626S3-6 | 626 | 501 | 569 | 455 | 2506C-E15TAG3 | |
| XG700S3-6 | 700 | 560 | - | - | 2806C-E18TAG1A | |
| XG750S3-6 | 750 | 600 | - | - | 2806C-E18TAG3 | |



10-2500KVA GENSETS WITH PERKINS ENGINE | |
Engine | |
Fuel Consumption 25% load L/H | 0.7-145 |
Fuel Consumption 50% load L/H | 1.5-246 |
Fuel Consumption 75% load L/H | 2.1-340 |
Fuel Consumption 100% load L/H | 2.7-470 |
More engine specfications,please download Perkins engine diesel generator leaflet 50HZ / 60HZ | |
Alternator | |
Voltage V | 50HZ:230/400V 60HZ:208/120; 220/127;416/240; 440/254; 480/277 |
Phase | AC Single Phase/AC Three Phase |
Brand | Stamford/Leroy somer/LEES |
Excitation Mode | Brushless(AVR) |
Power Factor (cosΦ) | 0.8(lag) |
Diesel Generator Set | |
Fuel Tank Capacity | 21.6 - 3760 Liters |
Control panel | DEEPSEA / COMAP |
Noise Level | 66-85 dbA/7m |
Type | Open, Silent(super Silent) or Containerized |
Option1 | Automatic Transfer Switch |
Option2 | MobileTrailer Type Diesel Generator |
Color | Customers' Requirement |
Certificate | CE/ISO9001 |
Warranty | 12 Months/1000 Hours |






Product features:
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing automatic emergency power supply system together with diesel generating sets. When prime power is cut off, it can automatically switch loads such as emergency illumination, security power and firefighting equipment to generating sets.
Continuous and rapid power supply is a basic and core function of ATS.
As long as there is power failure, ATS can ensure a continuous power supply.
When common power supply fails, ATS can quickly detect and timely automatically transfer.
When common power supply returns to normal, ATS will automatically transfer the load from the standby power supply to the common power supply.
When the power supply fails, ATS can automatically cut off power supply.
Application field:
It is applied in hospitals, banks, communication, airports, radio stations, hotels, factories and enterprises as the emergency power and fire extinguishing power.

The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.